Ultrasound Artifacts
Artifact Reduction
  • Artifact Reduction
Amplitude Shading
Amplitude shading is a method of reducing the side lobe levels in a transducer array. The shading usually causes the main beam to broaden by applying different voltages to the elements of the array.

See also Analog Output Signal.
• View DATABASE results for 'Amplitude Shading' (3).Open this link in a new window.
Apodization
Apodization is a method for reducing side lobes (lateral array elements) in some arrays. It gradually decreases the vibration of the transducer surface with distance from its center by improving the directivity. It is usually accomplished by using more power to excite the innermost elements.
• View DATABASE results for 'Apodization' (4).Open this link in a new window.
Frame Averaging
Frame averaging is a form of lowpass filtering. With frame averaging temporal variation are smoothed by addition of consecutive frames in a real-time mode.
• View DATABASE results for 'Frame Averaging' (3).Open this link in a new window.
Motion Discrimination Detector
The motion discrimination detector is used for signal processing in color Doppler systems to distinguish between Doppler shifts from moving blood and moving tissue.

See also Zero Crossing Detector.
• View DATABASE results for 'Motion Discrimination Detector' (3).Open this link in a new window.
Multiple Frame Trigger
The multiple frame trigger adjusts the acquisition of a series of consecutive frames, usually with ECG triggering. Multiple frame triggers are used in harmonic power Doppler modes to identify motion artifacts in contrast enhanced Doppler imaging.
• View DATABASE results for 'Multiple Frame Trigger' (3).Open this link in a new window.
Wall Filter
The wall filter is designed to exclude Doppler signals with low frequency, and high amplitude (highpass filter) from moving tissue, such as a vessel wall. Wall filter performance is critical for effectiveness of a color Doppler system.
• View DATABASE results for 'Wall Filter' (2).Open this link in a new window.
The significant problems we face cannot be solved at the same level of thinking we were at when we created them.
- Albert Einstein
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]