FFsonic UF-750XT
www.fukuda.co.jp/fukuda_e/products/uf-750xt.html From Fukuda Denshi Co., Ltd.;
'Fully software controlled Image Processing (F-XT technology)
Color Doppler & Power Doppler display available
Autofocus function for transmission
High-resolution SVGA display
Cine memory with 128 frames
Wide band Probe for multi frequency function
6-step STC adjustment
DICOM-compatible Ethernet port
3.5-inch 640MB drive for image filing'

• View DATABASE results for 'FFsonic UF-750XT' (2).Open this link in a new window.
Field of View
(FOV) The field of view is the plane or area depicted by the ultrasound transducer.
• View DATABASE results for 'Field of View' (4).Open this link in a new window.
Filling Gas
The gas in microbubbles is highly compressible and, when subjected to the alternating compression and refraction pressures that constitute an ultrasound pulse, microbubbles oscillate at their natural frequency at which they resonate most strongly. This is determined by their size but is also influenced by the composition of the filling gas.
Air, sulfur hexafluoride, nitrogen, and perfluorochemicals are used as filling gases. Most newer ultrasound contrast agents use perfluorochemicals because of their low solubility in blood and high vapor pressure. By substituting different types of perfluorocarbon gases for air, the stability and plasma longevity of the agents have been markedly improved, usually lasting more than five minutes.
• View DATABASE results for 'Filling Gas' (9).Open this link in a new window.
Filter
A filter in electronics is a circuit that only passes certain signals. In ultrasound is a filter a device to suppress acoustic or electromagnetic waves of certain frequencies, letting other frequencies pass, e.g. high pass filter, low pass filter. The high pass filter is the wall filter (also called thump filter) used in Doppler devices to eliminate low frequency Doppler shifts caused by clutter. For blood flow measurement, a low pass filter is often used to strip out high frequency noise, leaving only the biological components of interest. Frame averaging is a form of a low pass filter.
• 
View NEWS results for 'Filter' (1).Open this link in a new window.
• View DATABASE results for 'Filter' (16).Open this link in a new window.
First generation USCA
The first generation ultrasound contrast agents (UCA/USCA) do not pass the pulmonary vascular bed, and are therefore limited to the venous system and the right heart cavities after intravenous injection.
• View DATABASE results for 'First generation USCA' (5).Open this link in a new window.
Fa-FeFF-FFFF-FiFl-FoFo-FrFu-Fu
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]