 'Albunex' 
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Albunex' found in 3 articles
1
term [
] - 2 definitions [
]
Result Pages :
Albunex
Albunex and Infoson, used mainly in cardiac evaluations, are first generation one-pass-only contrast agents and have been replaced by the new-generation contrast media. Albunex and Infoson are the same sonicated human serum albumin microbubbles. Infoson is licensed and manufactured in Europe, while Albunex was produced in the USA.
Albunex, an air-filled microbubble with a denatured albumin shell (modified from air-filled albumin microspheres prepared from sonicated 5% human serum albumin), was the first FDA-approved contrast agent, but is no longer in production.
Cardiac shunts and valve regurgitations are often evaluated with Color Doppler Imaging (CDI), which also improved with injections of Albunex, but this agent is pressure-sensitive and does not recirculate. It is effectively a one-pass-only agent, limiting its clinical efficacy.

See also First generation USCA, Echocardiography and Contrast Enhanced Ultrasound.
Drug Information and Specification
DEVELOPER
INDICATION
Contrast sonography and Doppler-echocardiography
APPLICATION
Intravenous injection
TYPE
Microbubble
SHELL - STABILIZATION
Albumin
Air
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
History of Ultrasound Contrast Agents
The earliest introduction of vascular ultrasound contrast agents (USCA) was by Gramiak and Shah in 1968, when they injected agitated saline into the ascending aorta and cardiac chambers during echocardiographic to opacify the left heart chamber. Strong echoes were produced within the heart, due to the acoustic mismatch between free air microbubbles in the saline and the surrounding blood.
The disadvantage of this microbubbles produced by agitation, was that the air quickly leak from the thin bubble shell into the blood, where it dissolved. In addition, the small bubbles that were capable of traversing the capillary bed did not survive long enough for imaging because the air quickly dissipated into the blood. Aside from agitated saline, also hydrogen peroxide, indocyanine green dye, and iodinated contrast has been tested. The commercial development of contrast agents began in the 1980s with greatest effort to the stabilization of small microbubbles.

The development generations by now:
first generation USCA = non-transpulmonary vascular;;
second generation USCA = transpulmonary vascular, with short half-life (less than 5 min);
third generation USCA = transpulmonary vascular, with longer half-life (greater than 5 min).

To pass through the lung capillaries and enter into the systemic circulation, microspheres should be less than 10 μm in diameter. Air bubbles in that size range persist in solution for only a short time; too short for systemic vascular use.
The first developed agent was Echovist (1982), which enabled the enhancement of the right heart. The second generation of echogenic agents, sonicated 5% human albumin-containing air bubbles (Albunex), were capable of transpulmonary passage but often failed to produce adequate imaging of the left heart. Both Albunex and Levovist utilize air as the gas component of the microbubble.
In the 1990s newer developed agents with fluorocarbon gases and albumin, surfactant, lipid, or polymer shells have an increased persistence of the microspheres. This smaller, more stable microbubble agents, and improvements in ultrasound technology, have resulted in a wider range of application including myocardial perfusion.

See also First Generation USCA, Second Generation USCA, and Third Generation USCA.
Mallinckrodt, Inc.
www.mallinckrodt.com In June 2007 Tyco International Ltd. completed the separation of its healthcare business, which is named Covidien. Mallinckrodt, Inc. is now part of Covidien Ltd. The company makes and distributes products for respiratory care; bulk and dosage pharmaceuticals, primarily for pain relief and addiction therapy; and imaging agents for magnetic resonance, ultrasound, x-ray, and nuclear medicine applications. With worldwide manufacturing and distribution facilities and sales offices, Mallinckrodt, Inc. sells its products worldwide.
Albunex was one of the first marketed ultrasound contrast agents. Currently, Mallinckrodt discontinued the manufacturing and development of ultrasound contrast agents.

Ultrasound Contrast Agents:

Contact Information
MAIL
Covidien Imaging Solutions
675 McDonnell Blvd.
Hazelwood, MO 63042
USA
PHONE
US: (888)744-1414
International: +1-314-654-3177
FAX
+1-314-654-5380
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]