Filling Gas
The gas in microbubbles is highly compressible and, when subjected to the alternating compression and refraction pressures that constitute an ultrasound pulse, microbubbles oscillate at their natural frequency at which they resonate most strongly. This is determined by their size but is also influenced by the composition of the filling gas.
Air, sulfur hexafluoride, nitrogen, and perfluorochemicals are used as filling gases. Most newer ultrasound contrast agents use perfluorochemicals because of their low solubility in blood and high vapor pressure. By substituting different types of perfluorocarbon gases for air, the stability and plasma longevity of the agents have been markedly improved, usually lasting more than five minutes.
Thermal Effect
The thermal effect of ultrasound is caused by absorption of the ultrasound beam energy. As the ultrasound waves are absorbed, their energy is converted into heat. The higher the frequency, the greater the absorbed dose, converted to heat according the equation: f = 1/T where T is the period as in simple harmonic motion. Ultrasound is a mechanical energy in which a pressure wave travels through tissue. Heat is produced at the transducer surface and also tissue in the depth can be heated as ultrasound is absorbed.
The thermal effect is highest in tissue with a high absorption coefficient, particularly in bone, and is low where there is little absorption. The temperature rise is also dependent on the thermal characteristics of the tissue (conduction of heat and perfusion), the ultrasound intensity and the length of examination time. The intensity is also dependent on the power output and the position of the tissue in the beam profile. The intensity at a particular point can be changed by many of the operator controls, for example power output, mode (B-mode, color flow, spectral Doppler), scan depth, focus, zoom and area of color flow imaging. The transducer face and tissue in contact with the transducer can be heated.

See also Thermal Units Per Hour and Ultrasound Radiation Force.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]