1
term [
] - 4 definitions [
]
Result Pages :
Coherent Contrast Imaging
(CCI) A major limitation of the use of ultrasound contrast agents is the problem that signals from the microbubbles are mixed with those from tissue, so that the distribution of the microbubbles is not optimally displayed either in Doppler or gray scale.
Coherent contrast imaging is a high frame rate implementation of inverting the phase of alternate sound pulses and summing the resulting echoes. The symmetrical signals from linear reflectors are cancelled leaving those from non-linear scatterers, with the advantage that the cancellation is performed without the need to transmit two pulses per image line so that bubble destruction is minimized. Coherent contrast imaging yields best results in the vascular phase of phospholipid microbubbles (such as Definity and SonoVue).

See also Coherence.
Coherence
Coherence is the degree of phase agreement among waves. A coherent sound wave is one in which all of the signals are in phase.
Contrast Imaging Techniques
Many different contrast imaging techniques have been developed. Most are either variations, hybrids, or combinations of the following ultrasound techniques:

See also Coherent Contrast Imaging, Ultrasound Picture and Targeted Contrast Imaging.
Definity®
www.definityimaging.com/newsroom/newsroom/factsheet.asp From Lantheus Medical Imaging.
Activated DEFINITY® Injectable Suspension is indicated for use in patients with suboptimal echocardiograms to opacify the left ventricular chamber and to improve the delineation of the left ventricular endocardial border. The perflutren lipid microspheres exhibit lower acoustic impedance than blood and enhance the intrinsic backscatter of blood.
Echocardiography with Definity produced more detailed images of the heart in difficult-to-image patients versus echocardiography alone, and images obtained with the contrast agent provided a more accurate assessment of segmental wall motion compared with unenhanced images.

See also Coherent Contrast Imaging.

In August 2001 DuPont Pharmaceuticals Company received FDA approval.

Drug Information and Specification
RESEARCH NAME
DMP 115, MRX 115
INDICATION -
DEVELOPMENT STAGE
APPLICATION
Intravenous
Lipids:DPPA, DPPC,MPEG5000 DPPE
CHARGE
Negative
Octafluoropropane
MICROBUBBLE SIZE
98% < 10μm
PRESENTATION
Package contains four 2mL clear glass single-use vials.
STORAGE
Refrigerate 2−8 °C
PREPARATION
Activate through Vialmix agitation
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
DISTRIBUTOR
North America, Australia, South Asia, Middle East
SonoVue®
www.bracco.com/Bracco/Internet/Imaging/Ultrasound/ From Bracco Diagnostics, Inc.
SonoVue® was first launched in October 2001 and is now available in all European countries.
SonoVue is a second generation USCA, designed and optimized with regard to the resistance to pressure. SonoVue is an example of an important family of microbubbles whose membrane consists of phospholipids. SonoVue microbubbles are filled with sulfur hexafluoride (SF6), a gas which has a low solubility and diffuses slowly in blood for the gaseous phase of the microbubbles.
In particular, the SonoVue microbubbles, thanks to the high flexibility of their shell, are strongly echogenic in a wide range of frequencies and acoustic pressure and therefore can be used with both destructive and conservative contrast bubble specific imaging methods.

See also Coherent Contrast Imaging.
Drug Information and Specification
RESEARCH NAME
BR1
DEVELOPER
INDICATION -
DEVELOPMENT STAGE
APPLICATION
Intravenous
TYPE
Microbubble
Lipids: Macrogol 4000, DSPC, DPPG, Palmitic acid
CHARGE
Negative
Sulfurhexafluoride
MICROBUBBLE SIZE
99% < 11μm
PRESENTATION
Presentation 01(with integral Bio-Set transfer system) -25 mg of dry, lyophilized powder in an atmosphere of sulphur hexafluoride in a colorless Type I glass vial, with elastomeric closure and integral transfer system.Type I glass pre-filled syringe containing 5 ml sodium chloride 0.9%w/v solution for injection. - Presentation 02 (with separate MiniSpike transfer system)
STORAGE
No special precautions for storage
PREPARATION
Reconstitute with 5 ml saline
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
DISTRIBUTOR
USA, EU
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]