Medical Ultrasound Imaging
Friday, 17 May 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Averaging' p2
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Averaging' found in 9 articles
1
term [
] - 8 definitions [
]
Result Pages :
Filter
A filter in electronics is a circuit that only passes certain signals. In ultrasound is a filter a device to suppress acoustic or electromagnetic waves of certain frequencies, letting other frequencies pass, e.g. high pass filter, low pass filter. The high pass filter is the wall filter (also called thump filter) used in Doppler devices to eliminate low frequency Doppler shifts caused by clutter. For blood flow measurement, a low pass filter is often used to strip out high frequency noise, leaving only the biological components of interest. Frame averaging is a form of a low pass filter.
Partial Volume Artifact
A partial volume artifact is caused by the size of the image voxel. The loss of resolution is caused by multiple features present in the image voxel. In ultrasound imaging that occurs when the slice thickness is wider than the scanned structure. This artifact is also called slice thickness artifact or volume averaging artifact.

See also Ultrasound Picture.
Real-Time Mode
Real-time mode has been developed to present motion like a movie of the body's inner workings, showing this information at a high rate. The special real-time transducer uses a larger sound beam than for A, B or M-modes. A linear array transducer with multiple crystal elements displays real-time compound B-mode images with up to 100 images per second.
At each scan line, one sound pulse is transmitted and all echoes from the surface to the deepest range are received. Then the ultrasound beam moves on to the next scan line position where pulse transmission and echo recording are repeated.

See also Compound B-Mode, Pulse Inversion Doppler, and Frame Averaging.
Slice Thickness Artifact
The dimension of the ultrasound beam and the transducer array are the origin of the slice thickness artifact. This artifact is also called partial volume artifact or volume averaging artifact.

See also Validation.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]