Medical Ultrasound Imaging
Monday, 20 May 2024
• Welcome to
     Medical-Ultrasound-Imaging.com!
     • Sign in / Create account
 
 'Energy' p8
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W Z 
Searchterm 'Energy' found in 53 articles
1
term [
] - 52 definitions [
]
Result Pages :
...
...
Power
Power in ultrasound describes the energy generated by a wave or in a signal per unit of time. The power is measured in watts (W) and is proportional to the square of the amplitude.

See also Spatial Average Intensity, Ultrasound Radiation Force and Time Average Intensity.
Power Mode
In power mode the amplitude (power) of color Doppler signals is displayed, regardless of the velocity. Power does not have negative values and is independent of sampling frequency. An aliasing artifact does not occur in power mode images. Caused by plotting the quantity enhanced by echo contrast agents in a power map, power mode is often used in contrast Doppler ultrasound examinations.
Also known as energy mode.
Pressure
Pressure is the force per unit area applied on a surface in a direction perpendicular to that surface.
Pressure can also be described as a form of potential energy in a fluid. The maximum pressure of the fluid medium obtained during propagation of an ultrasonic pulse.
The negative peak pressure is the peak rarefaction pressure attained during the negative portion of a propagating ultrasound pulse in a medium such as tissue.
Sound pressure can be measured using a microphone in air and a hydrophone in water. The SI unit for sound pressure is the Pascal.
Blood pressure is the pressure exerted by the blood on the walls of the blood vessels.

See also Rarefactional Pressure, Low Intensity Pulsed Ultrasound, and Projector.
Projector
A projector (transmitter) converts the energy from the power amplifier (generator) into an acoustic pressure output. Projectors are usually driven near their resonance frequencies where they provide the highest acoustic output.
SONOLINE Sienna™
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-1&catalogId=-1&catTree=100001%2C12805%2C12761&level=0&productId=17280 From Siemens Medical Systems;
'This extremely flexible system supports targeted applications for OB/GYN, Radiology, Internal Medicine, Urology, and Prostate Brachytherapy. The large transducer selection, most with high-frequency capabilities, provides the right tool for general imaging, radiology, and internal medicine applications.'
Device Information and Specification
CONFIGURATION
Mobile, compact
SCAN MODES
DISPLAY MODES
Color flow, Power Doppler imaging, Transparent Energy Mode Imaging
Broadband, high-fidelity, multi-frequency, linear and curved
2.5 to 12.0 MHz
PROBE PORTS
Two - four
MEASUREMENT/CALCULATION FUNCTIONS
OB/GYN measurements and report package, off-line analysis
OPTIONAL PACKAGE
IMAGE PROCESSING
Zero Loss Flow Processing, 63-frame CINE Review with up to 63 B-mode frames and 31 color frames
IMAGE STORAGE/TRANSMISSION
Storage of patient report for archiving, reviewing, and editing, optional digital archive manager or digital network manager
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]