Bubble Specific Imaging
Bubble specific imaging methods rely usually on non-linear imaging modes. These contrast imaging techniques are designed to suppress the echo from tissue in relation to that from a microbubble contrast agent.
Stimulated acoustic emission (SAE) and phase / pulse inversion imaging mode (PIM) are bubble specific modes, which can image the tissue specific phase.
In SAE mode bubble rupture is seen as a transient bright signal in B-mode and as a characteristic mosaic-like effect in velocity 2D color Doppler.
PIM are Doppler modes and detect non-linear echoes from microbubbles. In pulse inversion imaging modes the transducer bandwidth extends, resulting in improved spatial resolution and more contrast.

See also Contrast Pulse Sequencing, Microbubble Scanner Modification, Narrow Bandwidth, Contrast Medium, Dead Zone.
• 
View NEWS results for 'Bubble Specific Imaging' (1).Open this link in a new window.
Directional Indicators
Color assignments can be switched on any ultrasound system and are used as directional indicators. The colors of red and blue indicates flow direction in color Doppler.
Red is encoded to represent flows toward the transducer.
Blue pixel encoding is used to depict flows away from the transducer.

See also Directional Color Power Doppler.
Doppler Ultrasound
Doppler ultrasound is a medical imaging technique for calculating the relative velocity between two points by measuring the frequency shift of a sound wave transmitted from one point to the other, based on the Doppler effect. Continuous or pulsed Doppler is frequently used to examine cardiovascular blood flow. The combination of routine 2D-mode and Doppler ultrasound allows a complete evaluation of the heart's anatomy and function (including the fetal heart). See also Doppler Fluximetry in Pregnancy.
Doppler ultrasound depends on the fact that if a moving object reflects the ultrasound waves, the echo frequencies are changed. A higher frequency is created if the object is moving toward the probe//transducer and a lower frequency if it is moving away from it. How much the frequency is changed depends upon how fast the object is moving. Doppler ultrasound shows the different rates of blood flow in different colors on a monitor in real time.
The major Doppler parameters are the peak systolic velocity and the end-diastolic velocity. The peak systolic velocity ratio compensates the variability between different patients and instrumentations.

Different Doppler and duplex techniques:
Dwell Time
The dwell time (also called ensemble length or packet size) is the transmitting duration of ultrasonic waves focused at one place or the Doppler samples for each line of sight. The reduction of the dwell time is of use if threshold pressures are exceeded.
The sensitivity to slow flow and accuracy of Doppler measurement increase with longer dwell times. With increased dwell times, the frame rates decrease and the capability of Color Doppler images to depict fast changes in hemodynamics is limited.
EUB-2000 B/W (Dop)
www.hitachimed.com/products/ultrasound/eub_2000.asp From Hitachi Medical Systems America Inc.;
The EUB-2000 B/W is a compact system capable of B-mode, M-mode, and optional with grayscale Doppler (EUB-2000 B/W Dop). This unit features intuitive operation, high mobility, and exceptional image quality. When color Doppler is not required, this system is an excellent choice for general purpose scanning.

Device Information and Specification
APPLICATIONS
General purpose, OB/GYN, EUS, brachytherapy
CONFIGURATION
Compact system
RANGE OF PROBE TYPE
Linear, convex, radial, bi-plane, echoendoscope longitudinal
PROBE PORTS
Two
B-mode, M-mode, simultaneous B/M-mode
IMAGING OPTIONS
Simultaneous imaging with biplane probes
ADDITIONAL FEATURES
Cine / multi memory, application specific measuring, etc.
OPTIONAL PACKAGE
PW/CW Doppler and auto-trace measurement (EUB-2000 B/W Dop), triple probe connector, digital image transfer, ECG/PCG module
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]