Hertz
(Hz) The standard SI unit of frequency.
Definition: The number of repetitions of a periodic process per unit time. It is equal to the old unit cycles or oscillations each second of a simple harmonic motion. The unit is named for the German physicist Heinrich Rudolf Hertz.
Larger units are
kilohertz (kHz) = 1 000 Hz
megahertz (MHz) = 1 000 kHz
gigahertz (GHz) = 1 000 MHz
SONOLINE G60 S™
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-1&catalogId=-1&catTree=100001%2C12805%2C12761&level=0&productId=19692 From Siemens Medical Systems;
'This high-performance, multi-specialty system supports and improves your daily ultrasound routine. Embedded DICOM creates the integrated foundation for a complete connectivity solution while MultiHertz™ multiple frequency imaging and Tissue Harmonic Imaging (THI) expands the clinical versatility of the system. Advanced applications such as stress echo, SieScape™ panoramic imaging, and transesophageal imaging can be seamlessly integrated.'
Device Information and Specification
CLINICAL APPLICATION
Widest range of applications
CONFIGURATION
Compact, mobile system
Wideband MultiHertz™ multiple frequency
RANGE OF PROBE TYPE
Standard and advanced
IMAGING OPTIONS
Tissue Harmonic Imaging with selectable frequencies, stress echo package, transesophageal echo
OPTIONAL PACKAGE
Software upgradeability to advanced clinical application
IMAGING ENHANCEMENTS
Precision MotionCapture, Synthetic aperture technology
STORAGE
Patient and image database management system
DATA PROCESSING
Parallel and quad signal processing
WEIGHT
Lightweight
Ultrasound
(US) Ultrasound is very high frequency sound above about 20,000 Hertz. Any frequency above the capabilities of the human ear is referred to as ultrasound.
Diagnostic ultrasound imaging uses much higher frequencies, in the order of megahertz. The frequencies present in usual sonograms can be anywhere between 2 and 13 MHz. The sound beam produce a single focused arc-shaped sound wave from the sum of all the individual pulses emitted by the transducer.

See also Medical Imaging.
Frequency
(F) The number of cycles of a periodic process per unit time. Frequency and wavelength are inversely related. The higher the frequency the smaller the wavelength. The frequency of ultrasound is expressed in units of hertz (Hz), where 1 Hz = 1 cycle per second.
The effect of different frequencies on tissue penetration:
The higher the frequency the less the penetration, the lower the frequency the greater the penetration. As frequency increases, resolution improves but the imaging depth or penetration decreases. The lower the axial resolution, the more detail can be seen.
Usual frequencies for pediatric ultrasound: 5.0mHz to 7.5mHz and 10mHz.
Usual frequencies for adult ultrasound: 2.0mHz to 3.0mHz.

See also Doppler Interrogation Frequency, Multi-frequency Probe, and Huygens Principle.
History of Ultrasound
The earliest introduction of vascular ultrasound contrast agents (USCA) was by Gramiak and Shah in 1968, when they injected agitated saline into the ascending aorta and cardiac chambers during echocardiographic to opacify the left heart chamber. Strong echoes were produced within the heart, due to the acoustic mismatch between free air microbubbles in the saline and the surrounding blood.
In 1880 the Curie brothers discovered the piezoelectric effect in quartz. Converse piezoelectricity was mathematically deduced from fundamental thermodynamic principles by Lippmann in 1881.
In 1917, Paul Langevin (France) and his coworkers developed an underwater sonar system (called hydrophone) that uses the piezoelectric effect to detect submarines through echo location.
In 1935, the first RADAR system was produced by the British physicist Robert Watson-Wat. Also about 1935, developments began with the objective to use ultrasonic power therapeutically, utilizing its heating and disruptive effects on living tissues. In 1936, Siemens markets the first ultrasonic therapeutic machine, the Sonostat.
Shortly after the World War II, researchers began to explore medical diagnostic capabilities of ultrasound. Karl Theo Dussik (Austria) attempted to locate the cerebral ventricles by measuring the transmission of ultrasound beam through the skull. Other researchers try to use ultrasound to detect gallstones, breast masses, and tumors. These first investigations were performed with A-mode.
Shortly after the World War II, researchers in Europe, the United States and Japan began to explore medical diagnostic capabilities of ultrasound. Karl Theo Dussik (Austria) attempted to locate the cerebral ventricles by measuring the transmission of ultrasound beam through the skull. Other researchers, e.g. George Ludwig (United States) tried to use ultrasound to detect gallstones, breast masses, and tumors. This first experimentally investigations were performed with A-mode. Ultrasound pioneers contributed innovations and important discoveries, for example the velocity of sound transmission in animal soft tissues with a mean value of 1540 m/sec (still in use today), and determined values of the optimal scanning frequency of the ultrasound transducer.
In the early 50`s the first B-mode images were obtained. Images were static, without gray-scale information in simple black and white and compound technique. Carl Hellmuth Hertz and Inge Edler (Sweden) made in 1953 the first scan of heart activity. Ian Donald and Colleagues (Scotland) were specialized on obstetric and gynecologic ultrasound research. By continuous development it was possible to study pregnancy and diagnose possible complications.
After about 1960 two-dimensional compound procedures were developed. The applications in obstetric and gynecologic ultrasound boomed worldwide from the mid 60's with both, A-scan and B-scan equipment. In the late 60's B-mode ultrasonography replaced A-mode in wide parts.
In the 70's gray scale imaging became available and with progress of computer technique ultrasonic imaging gets better and faster.
After continuous work, in the 80's fast realtime B-mode gray-scale imaging was developed. Electronic focusing and duplex flow measurements became popular. A wider range of applications were possible.
In the 90's, high resolution scanners with digital beamforming, high transducer frequencies, multi-channel focus and broad-band transducer technology became state of the art. Optimized tissue contrast and improved diagnostic accuracy lead to an important role in breast imaging and cancer detection. Color Doppler and Duplex became available and sensitivity for low flow was continuously improved.
Actually, machines with advanced ultrasound system performance are equipped with realtime compound imaging, tissue harmonic imaging, contrast harmonic imaging, vascular assessment, matrix array transducers, pulse inversion imaging, 3D and 4D ultrasound with panoramic view.

Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Medical-Ultrasound-Imaging.com
former US-TIP.com
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertise With Us
 [last update: 2023-11-06 01:42:00]